DISPLAYING SYSTEM INFORMATION
Display Alarm Memory
Alarms generated when the system is armed are recorded in the system's memory. To display the zones
that went into alarm, enter [ ][3]. The "System" light will FLASH, and the zones that went into alarm will be
displayed on the flashing Zone Lights. Note that the Alarm Memory will be cleared the next time the system
is armed.
Display Trouble Conditions
The PC550 constantly monitors itself to ensure proper operation. When a condition occurs that could
affect operation, the "System" light will come ON and the keypad will sound two short beeps every 10
seconds to warn of the trouble condition.
To silence the sounder, press the [#] Key. The keypad will be silenced, but the "System" light will remain
ON until the trouble condition is cleared.
To display the trouble conditions, enter [ ][2]. Trouble conditions are represented with the Zone Lights; if
a Zone Light comes ON, then that trouble condition is present:
Zone Light
Trouble
1
Battery Trouble
2
AC Failure
3
———–
4
Communications
Trouble
Note that the keypad sounder will not beep if only the AC Failure trouble is present.
8
Cause
Battery is low or disconnected
AC power is out
———–
System cannot communicate
with monitoring station
What To Do
Call for service
Check your fusebox or
circuit breakers; call for
service if the trouble
condition cannot be
corrected
———–
Call for service if trouble
does not correct itself