FoxESS T3 Manuel d'installation rapide
 Insert the plug assembly into the socket (inverter end) and lock each
other by the coupling twist.
DC Wiring
 Turn off the DC switch.
 Choose 12 AWG wire to connect the PV module.
 Trim 6mm of insulation from the wire end.
 Separate the DC connector as below.
 Insert striped cable into pin contact and ensure all conductor strands
are captured in the pin contact.
Plug
Pin contact Cable nut
T SERIES
5