Beam Patterns
Locating the Detector
Select a detector location that will provide the coverage required keeping in mind the
following potential problems.
• Do not aim the detector at reflective surfaces such as mirrors or windows as this
may distort the coverage pattern or reflect sunlight directly onto the detector.
• Avoid locations that are subject to direct high air flow such as near an air duct out-
let.
• Do not locate the detector near sources of moisture (steam or oil).
• Do not aim the detector such that it will receive direct or reflected (mirror) sunlight.
• Do not limit the coverage by large obstructions within the detection area such as
plants or filing cabinets.
Device Wiring
To connect the AMB-500, consult the wiring diagram below: