DF-C 63XXX & 61XXX Series User's Manual
Version 28.04.2019
Communication Protocol for DF-C61XXX Series Power Supplies
Command
Function
#G
Output START
#U
Output STOP
#D
Read the output status
#SXXXX
Set the output parameter. The first 4 digits are the
XXXX
frequency value (resolution 0.1Hz). The last 4 digits are
(S followed by 8
the voltage setting (resolution 0.1V). The number "0"
data digits.)
cannot be omitted in the command. For example setting
the parameters 101Hz 62V: #S10100620
#H
Switching to FS (0 – 300V) mode
#L
Switching to LV (0 – 150V) mode
#R
STOP output and CLEAR alarm
#C
Read the status of the power supply
Response
Received
Error
Received
Error
XXX.XHzXXX.XV
X.XXXAXXXX.XW
Error
Received
Error
Received
Error
Received
Error
Received
000
001
002
005
006
007
DSC-Electronics Germany • Georgstraße 36 • 53111 Bonn
DSC-Electronics Germany • Georgstraße 36 • 53111 Bonn
Description
The command is accepted
The power supply is not in standby mode or output may be
already active
The command is accepted
The power supply output is not active
The reply is a sequence of output frequency, voltage, current
and power. For example: 050.0Hz110.2V0.950A0099.5W
The power supply output is not active
The command is accepted
The power supply is not in standby mode, or the setting
parameter exceeds range
The command is accepted
Wrong command
The command is accepted
Wrong command
The command is accepted
Standby mode
Started
Setting mode
Short circuit alarm
Over temperature alarm
Over current alarm