2.6 Output Gain Switch
DSPeaker Servo 300 has three settings for different output levels. 
0dB is the default setting, which is suitable for far­field dynamics. It gives the highest peak 
sound pressure level. However, it also has creates servo­feedback which can sometimes 
result in higher noise level than desired for near field usage. 
­6dB   will   drop   the   output   level   by   6dB,   which   will   result   in   lower   noise   level,   but   also 
decreased maximum sound pressure level. This setting is ideal for listening in far­field in a 
very silent room where the ambient background noise is low.
­12dB will drop the output level by 12dB, which will result in very low noise level, but also 
decreased maximum sound pressure level. This is an ideal setting for listening in near­field 
monitoring where the distance to the speaker is less than 1 meter (3 feet). 
Rev. 1.6
21.06.2010
Page 13 (16)