Absolute Process Instruments APD 4300 D Manuel
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Absolute Process Instruments APD 4300 D. Absolute Process Instruments APD 4300 D 2 pages. Dc to dc transmitters, isolated, factory configured
DC to DC Transmitters, Isolated, Factory Configured
Input:
0-100 mV to 0-300 VDC, Bipolar Voltages, 0-1 mA to 0-1000 mADC
Output:
0-1 V to ±10 VDC or 0-1 mA to 4-20 mA
O Removable Plugs for Faster Installation
O Full 1200 V Input/Output/Power Isolation
O Zero and Span Output Calibration Potentiometers
O Input and Output LoopTracker
LEDs
®
O Functional Test Button with Remote Capability
O Built-In Loop Power Supplies for Input and Output
Applications
Q Convert, Boost, Rescale Process Signals
Q Isolate Single-Ended (Common Ground) PLC Inputs
Q Interface Process Signals with Panel Meters, PLCs,
Recorders, Data Acquisition, DCS, and SCADA Systems
DC Input Range
Factory configured, please specify input range or consult fac-
tory for special ranges.
See table on other side for common ranges.
Voltage:
0-100 mVDC
to
Bipolar voltage:
±100 mVDC
to
Current:
0-1 mADC
to
Input Impedance (Voltage)
200 kΩ minimum
Input Voltage Burden (Current)
1.25 VDC maximum
Common Mode Rejection
120 dB minimum
Input Loop Power Supply
15 VDC nominal, regulated, 25 mADC
Max. ripple, less than 10 mV
RMS
May be selectively wired for sinking or sourcing mA input
LoopTracker
Variable brightness LEDs indicate I/O loop level and status
DC Output Range
Factory configured, specify output range
Voltage, 10 mA max.: 0-1 VDC to
Voltage, M09 option: 0-10 VDC to
Bipolar voltage:
±1 VDC to
Current:
0-1 mADC to
0-20 mADC
20 V compliance, 1000 Ω at 20 mA
Output Calibration
Multi-turn zero and span potentiometers
±15% of span adjustment range typical
Output Loop Power Supply
20 VDC nominal, regulated, 25 mADC, <10 mV
May be selectively wired for sinking or sourcing mA output
Output Test/Override
Front button sets output to test level when pressed or via
external contact closure
Potentiometer adjustable 0-100% of span
Output Ripple and Noise
Less than 10 mV
ripple and noise
RMS
Linearity
Better than ±0.1% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.04% of span per °C stability
Response Time
Standard: 70 milliseconds nominal
DF option: Fast response time. Output noise levels will be
greater than standard specifications. Consult factory.
Isolation
1200 V
minimum
RMS
Full isolation: power to input, power to output, input to output
Housing and Connectors
IP 40, requires installation in panel or enclosure
For use in Pollution Degree 2 Environment
Mount vertically to a 35 mm DIN rail
Four 4-terminal removable connectors, 14 AWG max wire size
Power
85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum
A
A
P
P
BSOLUTE
BSOLUTE
ROCESS
ROCESS
File E145968
85-265 VAC, 60-300 VDC
model only
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
0-300 VDC
±10 VDC
Applications Link
0-1000 mADC
api-usa.com/apps
Free Factory
I/O Setup!
Dimensions
0-10 VDC
0.89" W x 4.62" H x 4.81" D
0-20 VDC
22.5 mm W x 117 mm H x 122 mm D
±10 VDC
Height includes connectors
Description
The APD 4300 accepts a DC voltage or current input and pro-
vides an optically isolated DC voltage or current output that is
linearly related to the input.
Typical applications include signal isolation, conversion, boost-
max. ripple
ing or a combination of the three. Full 3-way isolation (input,
RMS
output, power) makes this module useful for ground loop
elimination, common mode signal rejection or noise pickup
reduction.
The APD 4300 can be factory configured for 4-20 mA input and
4-20 mA output to solve signal isolation, ground loop, common
mode, or noise pickup problems for non-isolated PLC inputs.
For maximum versatility loop excitation power supplies are
included for the input and output. A mA input and a mA output
can be selectively wired for sinking or sourcing. This allows the
APD 4300 to work with any combination of sinking or sourcing
mA transmitters and sinking or sourcing mA receiving devices.
How to Order
All models are factory ranged
The APD 4300 is configured to your specifications.
Milliamp inputs and outputs can be field wired for sink or
source.
Model
APD 4300
APD 4300 D
Options—add to end of model number
M01
Input/output reversal, such as 4-20 mA input to
20-4 mA output
M09
High voltage output up to 20 V (specify range)
DF
Fast response time, consult factory.
U
Conformal coating for moisture resistance
I
I
NSTRUMENTS
NSTRUMENTS
Sink or Source
mA Output
Terminals for
5 6 7 8
Remote Output
Test/Override
Output LoopTracker
LED
Adjustable Output
Test/Override
Function
Zero and Span for
Output
Input LoopTracker
LED
Custom I/O Ranges
Sink or Source
mA Input
9 10 11 12
Pb
Lead
Free
Universal Power
Input
Factory configured—specify
input range
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
APD 4300
Quick Link:
1 2 3 4
13 14 15 16
LoopTracker
API exclusive features include two LoopTracker LEDs (green for
input, red for output) that vary in intensity with changes in the
process input and output signals. These provide a quick visual
picture of your process loop at all times and can greatly aid in
saving time during initial startup and/or troubleshooting.
Functional Test
An API exclusive feature includes the Functional Test Button
to provide a fixed output (independent of the input) when held
depressed. The test output level is potentiometer adjustable
from 0 to 100% of output span. The functional test button
greatly aids in saving time during initial startup and/or trouble-
shooting.
The functional test can also be enabled with a customer-
supplied external contact closure across terminals 5 and 6.
This allows remote testing of the output or, for example, a
PLC-controlled manual override setting.
Please specify
Model
Input range
Output range
Options as required
Output
85-265 VAC or 60-300 VDC
Factory configured—specify
output range
9-30 VDC or 10-32 VAC
Accessory—order as separate line item
API BP4 Spare 4-terminal plug, black
api-usa.com
api-usa.com/4300
Removable Plugs
See Wiring
Diagrams on
Next Page
Power
© 11-19