2.2.3 – Output to a Balanced Destination
To connect to a balanced input on a destination device, connect the positive, negative, and ground connections of both
the unDIO2x2 output to the destination input respectively.
Figure 6 - Output to Balanced Destination Connection
2.2.4 – Output to an Unbalanced Destination
To connect the unDIO2x2 outputs to a 2-wire unbalanced input, connect the positive output to the destination's
positive input and connect the grounds together through the cable shield. Leave the unDIO2x2 negative output
floating.
Figure 7 – Output to Unbalanced Destination