NOTE: When testing older model diesel
engines, the users need to run the engine
at 2500 rpm for 15 seconds. The display
screen will show RUN THE ENGINE UP
TO 2500 RPM 15 SEC.
10. The tester will test the amount of ripple
from the charging system to the battery.
One of the three following results will be
displayed along with the actual reading
measured:
RIPPLE DETECTED NORMAL – The
diodes are functioning properly in the
alternator/starter.
NO RIPPLE DETECT – The diodes are
functioning properly in the alternator/starter.
RIPPLE DETECTED HIGH – One or more
of the diodes in the alternator are not
functioning properly.
11. Press ENTER to continue testing the
charging system with accessory loads.
One of the three following results will
be displayed along with the actual
reading measured:
PROBLEM
Printer does not
print.
Display shows POWER
LOW.
Display shows LOAD
ERROR.
Display shows LOW
CHARGING VOLTS
WHEN AT IDLE.
Display shows CHARGING
SYSTEM NORMAL WHEN
AT IDLE.

TROUBLESHOOTING

POSSIBLE CAUSE
Paper may be reversed. This is
a thermal printer.
Paper is jammed.
The paper is the wrong type.
Batteries have run out of
power.
Connection is loose or heavily
corroded.
Battery capacity is more than
2000 CCA or 200 Ah.
Battery may be very hot.
Clamps are not connected
properly.
The alternator is not providing
sufficient current to the battery.
The system is showing normal
output from the alternator.
6
ALT. LOAD VOLTS HIGH – The output
voltage from the alternator to the battery
exceeds the normal limits of a functioning
regulator.
ALT. LOAD VOLTS LOW – The alternator
is not providing sufficient current for the
system's electrical loads and the charging
current for the battery.
ALT. LOAD VOLTS NORMAL – The
system is showing normal output from the
alternator. No problem detected.
12. Press ENTER and the display will show
TEST OVER, TURN OFF LOADS AND
ENGINE. Press ENTER to continue.
13. Turn off all accessory loads and the
engine. Press ENTER to continue.
14. The screen will show PRINT RESULTS
and a YES or NO option. Select YES to
print results. After you've printed
the number of copies you need, select
NO to return to the first screen.
15. To end the test, remove the clamps
from the battery posts.
Remove the paper roll, turn it
over and re-insert it.
Pull the paper out slowly from
the roll side of the tester and
re-insert it properly.
Use thermal paper.
Replace the six 1.5V AA
batteries before starting the test.
Clean or replace the cable and
retest.
Try different battery with
smaller capacity.
All the battery to cool off.
Connect the clamps properly.
Have the alternator checked.
No problem is detected.
SOLUTION