Attero Tech CommandHub Manuel de l'utilisateur - Page 19
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Attero Tech CommandHub. Attero Tech CommandHub 20 pages. Unify proxy device for control and routing
4.2.10 – Get Clock State
This command is used request the clock status for a device.
Start
Character
0x02
Start
Command
Character
(ASCII)
0x02
RCLK
Example command:
<START> GCLK unD32-010203 <STOP>
Example response:
<START> RCLK 2 <CR> Primary,Master,No <CR> Secondary,Slave,No <CR> <STOP>
If the interface is not supported, the response would be NA. (example)
Response:
<START> RCLK 2 <CR> Primary,Master,No <CR> NA <CR> <STOP>
Example error response: [device not present]
<START> RCLK 1 [NA] Device Not Present <CR> <STOP>
© Attero Tech LLC 2015
Command
(ASCII)
GCLK
Table 17 - GCLK Command Format
# of Interfaces
{Interface, State,
Preferred}
(1 ASCII) + <CR>
ASCII + <CR>
"Interface, State,
2
Preferred"
Table 18 - GCLK Response Format
Page 18
Device Name
(ASCII) + <CR>
"Device Name"
0x03 0x07 0x04
{Interface, State,
Preferred} [n]
ASCII + <CR>
"Interface, State,
Preferred"
CommandHub
User Manual
Stop
Character
Stop
Characters
0x03 0x07 0x04
614-00019-01