Backup Power Mode Operation
The power supply for the Backup Power mode takes approximately
two hours of operation in the Normal Mode to fully charge the
backup power supply from the loop supply.
If loop power is lost, the gauge will automatically
switch to the Backup Power mode.
The low power indicator will flash, and the Loop-
Tracker LED will be off. The pressure will display
for 15 seconds, then the gauge will shut off.
To power up the gauge, press and release the
SEL button.
After initialization, the gauge will indicate the
applied pressure for 15 seconds.
To power-up the gauge for a longer period of time
and override the auto shutoff, press and hold the
SEL button until the display indicates On.
The gauge will indicate the pressure until the
backup power is depleted. A fully charged
backup supply will last up to 40 minutes.
Press SEL to manually power OFF the gauge.
The gauge will return to Normal Mode when loop
power is restored.
Out-of-Range Indications
If excessive vacuum is applied to a pressure-
only gauge, the display will indicate an out-of-
range indication of –Err. Applying vacuum to
a pressure-only gauge can damage the sensor.
If excessive vacuum is applied to a vacuum-
pressure gauge, the display will indicate an out-
of-range indication of – I – – – or –I.–.–.– will
be displayed depending on model.
If 112.5% over-range pressure is applied, an
out-of-range indication of 1 – – – or 1.–.–.– will
be displayed depending on model.
Enter Configuration Pass Code
When a pass code is required, the upper display will indicate _ _ _ _ ,
and the lower display will indicate CFGPC, CALPC, or TSTPC
depending on the feature being accessed.
To cancel, press the SEL button without entering any numbers. If no
buttons are pressed, the gauge will revert to normal operation after
15 seconds. To proceed, enter the user-defined pass code. 3510 is
the factory default, but it is user-modifiable.
The first position will be blinking.
Use the s or t buttons to set the left-most
digit to 3.
Press and release the SEL button to index to the
next position.
The 3 will remain, and the second position will
be blinking.
Use the s or t buttons to select 5.
Press and release the SEL button to index to the
next position.
3 5 will remain, and the third position will be
blinking.
Use the s or t buttons to select 1.
Press and release the SEL button to index to the
next position.
3 5 1 will remain, and the fourth position will
be blinking.
Use the s or t buttons to select 0.
Press and release the SEL button to proceed with
configuration procedures.
Note: If an incorrect pass code is entered, the
gauge will return to the start of the pass code
entry sequence.
C E CO MP
Div. of
Zero/Tare Mode
Zero/Tare applies to gauge reference models only. Absolute refer-
ence gauges do not use the zero feature since they read atmo-
spheric pressure under normal conditions.
i 0 0 . 0
This feature can be enabled or disabled in Gauge Configuration.
The gauge must be in the Normal Mode with the gauge port
psig
exposed to normal atmospheric pressure.
s
t
SEL
TEST
While in the Zero Tare mode, the gauge will not respond to any
changes in pressure. The loop current will maintain its last value.
s
t
SEL
TEST
i 0 0 . 0
Press and hold both the s and t buttons.
psig
Then press the SEL button.
s
t
SEL
TEST
or
Release all buttons when oooo is displayed.
n
o
s
t
SEL
TEST
The display will indicate a new zero tare value
hold
with Z OFF (zero offset) on the lower display.
O F F
To exit with no changes, press SEL.
If not within approximately 3%
SEL
TEST
s
t
full scale of zero, Err0 will be
displayed and no changes are
allowed. Pressure must be removed from the
gauge, or it must be recalibrated.
-E r r
To remove the existing zero tare value, press and
psig
release the t button. The display changes to
- I . - . -. - . -
zero. The Normal Mode may indicate a non-zero
value since zero correction has been removed.
psig
- I - - - -
To restore the newly calculated zero tare value,
psig
press and release the s button.
I .- . - . - . -
psig
I - - - -
psig
To exit the Zero Tare mode and return to the
Normal Mode, press and release the SEL button.
Test Function
The Test Mode will allow setup and testing
of the current loop without having to alter the
_ _ _ _
system pressure.
From the Normal Mode with applied pressure
being displayed, press and hold the TEST button.
3 _ _ _
SEL
TEST
s
t
While holding the TEST button, press the SEL
then
or
3 _ _ _
button.
When the display indicates – – – – , release
both buttons.
3 5 _ _
If a pass code is required, the upper display will
indicate _ _ _ _ with the left-most position blink-
ing, and the lower section will indicate TSTPC
s
t
SEL
TEST
(Test Pass Code). See the "Enter Configuration
then
or
Pass code" section of this manual to enter the
3 5 _ _
pass code and continue.
Next, the upper display will indicate the applied
pressure and the units display will be blinking.
3 5 I _
While the TEST button is pressed, the display and
loop current are switched, independent of the
actual pressure, to a level determined by the test
SEL
TEST
s
t
setting. TEST is indicated on the lower display.
then
or
Note: The gauge will not respond to changes in
3 5 I _
applied pressure while the TEST button is held.
Pressing the s or t buttons while pressing the
3 5 I 0
TEST button will raise or lower the test value.
When the TEST button is released, the setting is
stored in non-volatile memory and the gauge will
SEL
TEST
s
t
operate normally.
then
or
Press SEL to exit the Test Mode and return to
the Normal Mode.
A
P
BSOLUTE
ROCESS
0 . I
psig
SEL
TEST
s
then
hold
press
oooo
psig
SEL
TEST
s
0 . I
Z OFF
SEL
TEST
s
E r r 0
0. 0
Z off
SEL
TEST
s
or
0 . I
Z off
s
SEL
TEST
0. 0
Z off
s
SEL
TEST
exit
50 . 0
psig
SEL
TEST
s
hold
50 . 0
psig
s
SEL
TEST
both
- - - -
_ _ _ _
TSTPC
or
50 . 0
psig
i 0 0 . 0
test
SEL
TEST
s
i 0 0 . 0
TEST
SEL
TEST
s
hold
or
SEL
TEST
s
exit
1220 American Way Libertyville, IL 60048
I
NSTRUMENTS
F16LSC, F16LSCN
Gauge Configuration
The gauge must be powered by a loop supply during configuration.
Press and hold the TEST and s buttons, then
press the SEL button.
Release all buttons when the display indicates
CFG. The gauge firmware version is also dis-
played.
t
The display prompts for entry of the configura-
tion pass code (CFGPC), with the first under-
score blinking. To enter the 4 digit pass code,
see the Enter Configuration Pass Code section.
Factory/User Configuration
Upon successful pass code entry, the upper
t
display will be blank, and the lower will display
USER. Use the t or s buttons to select
USER or FCTRY.
With USER selected, the gauge configuration
t
can be modified as described below.
To reset the gauge to the factory configuration,
press SEL while FCTRY is displayed. The gauge
will restart with the factory configuration restored.
Gauge Type Configuration
This applies to gauge reference vacuum/pres-
sure models only.
Use the t or s buttons to select:
t
-/+EU
Vacuum is indicated as a negative
number in the selected engineering units
CMPND
Vacuum is displayed as negative
InHg and pressure in PSIG.
t
Press and release the SEL button to move to the
next parameter.
Engineering Unit Selection
This is skipped if CMPD was selected.
Use the t or s buttons to select the engineer-
t
ing units available for the range of the gauge:
Press and release the SEL button to move to the
next parameter.
Zero Tare Enable/Disable
This is not used for absolute reference gauges.
Use the t or s buttons to select:
t
ZTARE
Zero Tare function enabled.
NOZTR
Zero Tare function disabled.
Press and release the SEL button to move to the
next parameter.
Test Function Pass Code Enable/Disable
Use the t or s buttons to select:
t
TSTPC Pass code required for Test Mode.
NOTPC No pass code required for Test Mode.
Press and release the SEL button to move to the
next parameter.
Range Lower Limit Adjust
The upper display will indicate the pressure
value corresponding to 4 mA loop current. The
lower section will display RNGLO.
Use the t or s buttons to display the desired
pressure equal to a 4 mA output:
Press and release the SEL button to move to the
next parameter.
Range Upper Limit Adjust
The upper display will indicate the pressure
value corresponding to 20 mA loop current. The
t
lower section will display RNGHI.
Use the t or s buttons to display the desired
pressure equal to a 20 mA output:
Press and release the SEL button to save the
user configuration and restart the gauge.
t
The configuration parameters will not be saved if
the procedure is interrupted before completion.
t
cecomp.com
800-942-0315
i 0 0 . 0
SEL
TEST
s
t
and
then
C F G
V 04E
s
t
SEL
TEST
_ _ _ _
CFGPC
USER
or
FCTRY
s
t
SEL
TEST
then
or
+/- EU
or
CMPND
SEL
TEST
s
t
then
or
PSIG
SEL
TEST
s
t
then
or
ZTARE
or
NOZTR
s
t
SEL
TEST
then
or
TSTPC
or
NOTPC
SEL
TEST
s
t
then
or
o . 0 0
RNGLO
SEL
TEST
s
t
then
or
o . 0 0
RNGHI
SEL
TEST
s
t
then
or
restart
i 0 0 . 0
PSIG
s
t
SEL
TEST
normal operation