Selecting the operating mode
The programmable switch has 2 operating modes: manual (MAN)
and automatic (AUTO). To switch mode, press the MODE button for 3
seconds.
Manual Mode
In Manual mode, the timer operates like a regular switch. Briefly
press the MODE button to activate or deactivate the load. (If you
have connected a remote switch to the timer for a 3-way installation,
the switch can also be used to activate or deactivate the load.) The
mode indicator (MAN) and the state (ON or OFF) are displayed.
Automatic Mode
In Automatic mode, the timer follows the programmed schedule (see
section 6). The mode indicator (AUTO), the state (ON or OFF) and
the current program number are displayed.
To temporarily override the programmed schedule, press the MODE
button or use the 3-way installation switch (if connected). The new
state indicator will flash to show that this state is temporary. The
override remains in effect until you press the MODE button (or use
the remote switch) or until the beginning of the next program.
Programming
You can set up to 7 programs. To set a program, you need to enter its
start time (ON) and its end time (OFF).
Press the PGM button to display a program and its On or Off
time. For example, when you first press PGM, program number
1 (P1) and its On time (ON) will appear. - : - - will appear instead
of the time if the program is not set (inactive).
Press the DAY button to select the day to which you want to
apply the program.
NOTE: If you want to apply the same program to each day of the
week, press DAY until all the days are displayed. (This still
counts as 1 program, not 7.)
Press the HOUR and MIN buttons to set the ON time (time when
you want the lights to turn on). If you have selected the 12-hour
format, ensure that PM appears on the screen when an
afternoon time is displayed.
After you have programmed the ON time, press the PGM button
to display the OFF time (time when you want the lights to turn
off).
Repeat steps 3 through 5 to program the OFF time.
NOTE: If you have used only one program to set the ON time for
all 7 days, the OFF time of that program will automatically apply
to all 7 days.
To set another program, repeat steps 2 through 6. Programs that
are not set will remain inactive.
Press the MODE button to return to normal operation.
Clearing a Program
Press the PGM button until the desired program is selected. Hold the
PGM button for 3 seconds. - : - - appears when the program is
erased.
TI040
5.
Technical specifications
Supply: 120/208/240 VAC, 50 / 60 Hz
Maximum
load: See section 1
Output: Double Pole Single Throw (DPST)
Input (for 3-way installation
Battery
backup: During a power outage, the screen is blank but the
programs are retained by an internal rechargeable battery.
Operating temperature
Enclosure
type: 3R
Certifications: CSA & UL
Warranty
Honeywell warrants this product, excluding battery, to be free from defects in
the workmanship or materials, under normal use and service, for a period of
three (3) years from the date of purchase by the consumer. If at any time
during the warranty period the product is determined to be defective or mal-
functions, Honeywell shall repair or replace it (at Honeywell's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to the place
from which you purchased it, or
(ii)
contact Honeywell. Honeywell will make the determination whether the
product should be returned, or whether a replacement product can be
6.
sent to you.
This warranty does not cover removal or reinstallation costs. This warranty
shall not apply if it is shown by Honeywell that the defect or malfunction was
caused by damage which occurred while the product was in the possession of
a consumer.
Honeywell's sole responsibility shall be to repair or replace the product within
the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY
LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY,
FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR
ANY OTHER FAILURE OF THIS PRODUCT. Some provinces, states or
regions do not allow the exclusion or limitation of incidental or consequential
damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRAN-
TIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
THREE-YEAR DURATION OF THIS WARRANTY. Some provinces, states or
regions do not allow limitations on how long an implied warranty lasts, so the
above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights
which vary according to the province, state or region.
Customer Assistance
If you have any questions on the product installation or operation,
contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: 1-800-831-2823
Email: [email protected]
For more information on our products, go to
Printed in USA
only): Requires a dry contact
range: -40 °C to 50 °C (-40 °F to 122 °F)
www.aubetech.com