7: Operation: Global Settings
• All buttons on the ADE-32 have 2 behaviours. The 'local' behavior, indicated by the black writing
immediately below each button, is accessed by a 'single click' and is unique to the settings for
each output.
The 'global' behavior, indicated by the grey writing immediately below each button, is accessed
by a 'click & hold' and sets that parameter globally for the entire module.
Notice that when a click & hold is performed the 3 LEDs above the EDIT button will perform a quick
flash routine moving left to indicate a particular behavior has been turned off and right to indicate
a particular behavior has been turned on.
The following text refers to global behavior accessed by a click & hold.
1) EDIT [LATCHING]
A click & hold on the EDIT button will change the behavior for the OUTPUT: TYPE, DIV/MULT
QUANTIZE and OFFSET QUANTIZE knobs between 'non-latching' and 'latching'.
Non-latching means that when a knob is turned the setting for that output will instantly update to
reflect the current knob position.
Latching means that no update will take place until the knob has been turned to the position that
matches the setting for that knob.
2) OPTION [S&H CV RANGE]
A click & hold on the OPTION button will alternate the behaviour of the S&H CV output type between
bipolar (+/- 5V) and unipolar (0-1V).
The unipolar values are quantized to whole notes across a 1 octave range.
3) DIV/MULT QUANTIZE [BEAT/BAR]
A click & hold on the DIV/MULT QUANTIZE button will change the behaviour of the CLOCK DIV/MULT
knob between BEAT i.e. – the clock division/multiple will update as soon as the knob is turned and
BAR – i.e. the clock division/multiple will update at the first beat of the next bar.
4) OFFSET QUANTIZE [BEAT/BAR]
A click & hold on the OFFSET QUANTIZE button will change the behaviour of the OFFSET QUANTIZE
knob between BEAT i.e. – the phase offset will update as soon as the knob is turned and BAR –
i.e. the phase offset will update at the first beat of the next bar.