3onedata IMC100M-2GT1GF Manuel d'installation rapide - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel d'installation rapide pour {nom_de_la_catégorie} 3onedata IMC100M-2GT1GF. 3onedata IMC100M-2GT1GF 3 pages. Industrial media converter

3onedata IMC100M-2GT1GF Manuel d'installation rapide
1.
Power indicator
2.
LFP indicator
3.
100M interface connection status indicator
4.
100Base-FX fiber port
5.
10/100Base-T(X) copper port
6.
Gigabit interface connection status indicator
7.
1000Base-X 1×9 fiber port
8.
10/100/1000Base-T(X) copper port
9.
1000Base-X SFP slot indicator
10.
1000Base-X SFP slot
11.
DIN-Rail mounting kit
12.
DC power terminal block
13.
DIP switch
14.
Grounding screw (Protective grounding)
15.
AC power terminal block
【Mounting Dimension】
Unit: mm
Note before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Step 1 Check if the DIN-Rail mounting kit is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert the
top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3 Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1 Device power off.
Step 2 After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Note before powering on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
【Power Supply Connection】
This device provides 3-pin 7.62mm pitch
terminal block, which supports non-polarity and
anti-reverse connection.
Note:
Before connecting to power supply, confirm the power
supply type the product supports.
DC power supply
Voltage range: 24VDC (12~48VDC)
The pin definitions of DC power supply are shown as follows:
PIN
1
2
Definition
V+
FG
AC power supply
Power supply value: 220VAC
The pin definitions of AC power supply are shown as follows:
PIN
1
2
Definition
N
FG
【DIP Switch Settings】
Provide 4 pins DIP switch for function settings,
where "ON" is enable valid terminal. The device
needs to be powered on again to change the
status of DIP switch. DIP switches definition as follows:
DIP
ON Status
1
Reserved
Enable flow control
2
function
Set the device to remote
mode. PWR indicator
3
would blink when device
is in remote mode.
4
Reserved
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Indicate
Description
3
V-
3
L
OFF Status
Disable
flow
control
function
Set the device to local
mode. PWR indicator is
on when device is in
local mode.