3onedata ICS5028G-4XGS-8GC Manuel d'installation rapide - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel d'installation rapide pour {nom_de_la_catégorie} 3onedata ICS5028G-4XGS-8GC. 3onedata ICS5028G-4XGS-8GC 3 pages. Industrial layer 3 ethernet switch

3onedata ICS5028G-4XGS-8GC Manuel d'installation rapide
This product adopts rack-mounting, mounting steps as
below:
Step 1
Select the device mounting position and ensure
enough mounting size is reserved.
Step 2
Adopt 4 bolts to install the mounting lugs in the
device position as figure below.
Step 3
Place the device in the rack; adopt 4 bolts to fix two
sides mounting lugs in the rack.
Step 4
Check and confirm the product is firmly installed on
the rack, then mounting ends.
【Disassembling Device】
Step 1
Power off device.
Step 2
Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Step 3
Remove
the
device
away
disassembling ends.
Note before powering on:
Power ON operation: First insert the power supply terminal
block into the device power supply interface, and then plug
the power supply socket and power on.
Power switch "—" means power ON, "O" means power OFF.
Power OFF operation: First, put the powers switch to the "O"
side and then disconnect the power supply. Finally disconnect
the connector between the device and the power cord. Please
notice the operation order above.
【Power Supply Connection】
AC power supply
This device provides 2 AC power supply access
interfaces which come with a switch. The power
supply input range is 100~240VAC/DC.
DC power supply
occupies 3 pins and supports anti-reverse connection.
Power supply range: 36~72VDC
【Restoring Default Settings】
RESET is restoring default settings button. Restoring default
settings steps as follows: Press and hold the RESET button,
disconnect the power supply and then power on the device,
wait for about 3~4 seconds to restore the factory settings.
【Relay Connection】
information occurs. The product supports 2-way relay alarm
output, externally connected to alarm lights or alarm buzzer
or other switching value collecting device in order to timely
from
the
rack,
notify operators when the alarm occurs.
【Console Port Connection】
The series products provide 1 program debugging port
based on RS-232 serial port which can conduct device CLI
command management after connecting to PC. It adopts
RJ45 interface, its pin definition is showed as follows:
Pin No.
Definition
This device provides 2 DC power
supplies which are 5-pin 5.08mm pitch
terminal
blocks.The
power
supply
R+ and R- are the relay alarm output
section. They are open circuit in normal
non alarm state, closed when any alarm
2
3
5
TXD
RXD
GND
- 2 -
【Checking LED Indicator】
The series products provide LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
State
Description
Power supply is connected or
ON
running normally
P1
Power supply is disconnected or
OFF
running abnormally
Power supply is connected or
ON
running normally
P2
Power supply is disconnected or
OFF
running abnormally
Blinking
System is running normally
OFF
System is not running or running
RUN
abnormally
ON
System is running abnormally
Power supply or the port's link is
ON
alarming.
ALM
Power and the port's link exist no
OFF
alarm
ON
Port connection is active
Link
(G1-G24,
Blinking
Data transmitted
X1-X4)
OFF
Port connection is not active
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
network
between
them
accessed.
Step 2
Enter device's IP address in the address bar of
can
be
mutually