Anyload EC100 Manuel d'utilisation - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Anyload EC100. Anyload EC100 12 pages. Counting scale
Également pour Anyload EC100 : Manuel d'utilisation (6 pages)

5.2.1 Number settings:

The setting is used in the case of counting the unknown unit weight.
Place a certain number of samples on the platter. Note the total weights
reading for these samples displaying in the WEIGHT display. Set the
number of samples u s i n g numeric keys. T h e s et number will be
shown in UNIT WEIGHT display. Pressing the [SAMPLE/UNIT] key, t h e
UNIT WEIGHT display will show the average unit weight per piece and
TOTAL display will show the number of samples.
5.2.2. Unit weight setting:
This setting is used in the case the unit weight is already known. Set
the unit weight data then numbers will display in UNIT WEIGHT. Press
[UNIT WEIGHT] key to accept the settings. To cancel previous unit
weight and sample setting, press [CE] key.

5.3. Alarm Function

To avoid counting error, the scale has useful alarm function to alert the
operator of possible counting inaccuracy in case of shortage of number of
samples or shortage of sample unit weight

5.3.1. Sample number alarm:

Lack of Sample light will turn on if the total weight of sample is below
the limit value. Add pieces of samples until the lack of sample
disappears. Then set the new number of samples through numeric key
then press [SAMPLE/UNIT] key.
FREE SAMPLE FUNCTION is the same as above. Scale will automatically
adjust and calculate new average unit weight if operator add samples
slowly with the numbers.
FREE SAMPLE FUNCTION will not work if the displayed number exceeds
1,000,000 pieces

5.3.2 Unit weight alarm:

Lack of Piece Weight light will turn on if the average unit weight or set
unit weight is not enough for accurate counting operation. Operator may
use scale even the light is on, but counting error may happen.

5.3.3. Alarming by press [QTY/SET]:

THE SCALE has useful check function to alert operator that the total piece
counts quantity has reached the lower limit and the upper limit desired.
This function is designed for packing purpose. For example, if the
5 |
ANYLOAD EC100 Counting Scale Operations Manual (V1611)