Anyload OCS-01-S Manuel de l'utilisateur - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Anyload OCS-01-S. Anyload OCS-01-S 13 pages. High resolution digital crane scale
High Resolution Digital Crane Scale
backlight
flashes
no action taken
after key
pressed
weight reading
not stable
weight reading
not zero when
no load
large error in
weight reading
defective mainboard
discharged battery
scale is disturbed
defective key
load in motion
weak Anti-Motion
damped loadcell or
mainboard
defective mainboard
discharged battery
load-cell stressed too
long
loadcell drifts
scale not zeroed before
applying load
wrong unit
scale requires
calibration
defective loadcell or
mainboard
contact representative
replace battery
re-plug power cable
contact representative
keep load stable
change Anti-Motion level
dry loadcell or mainboard
contact representative
replace battery
hang scale in storage
contact representative
Manual Zero scale before
loading
switch to correct unit
calibrate scale
contact representative
User Guide