DESCRIPTION OF PRODUCT

The 526 series switchover is an automatic switchover system designed to provide a continuous supply of
high purity gas. This unit may be used with one cylinder per side, or used with a manifold that has increased
storage capacity. The inlet of the switchover system may be purchased with open ports, diaphragm valves,
manifold con nec tors, or fl exible pigtails. The system, when con fi g ured with manifold connectors, is for use
with the 528 Series Manifl ex system. If constant outlet pressure is required, a regulator will need to be
installed as part of the switchover system (as with the 526 XX1X through XX7X models) or down stream
after the switchover system. If the system includes the optional remote alarm, refer to ADI 5106 or ADI
8824 for installation and operation instructions. The standard switcho ver system will main tain a vari able
line pres sure within the values shown in the table below:
MODEL NUMBER
526 2X0X
526 3X0X
526 4X0X
526 5X0X
526 7X0X
Standard System
Confi guration
Diaphragm Valve
OUTLET PRESSURE (without Line Regulator)
35-95 PSIG
65-135 PSIG
160-235 PSIG
445-545 PSIG
120-185 PSIG
Outlet
Inlet Gauge,
Left Bank
Relief Valve
Manifold Connector
Figure 1 - System Confi gurations and Parts
2.4-6.5 BAR
4.5-9.3 BAR
11-16.2 BAR
30.7-37.6 BAR
9.0-12.8 BAR
System Confi guration
with Line Regulator
Line Pressure Gauge
R
®
PRECISION GAS CONTROLS
WWW.CONCOA.COM
R
Inlet
Auxiliary
Relief Valve
Inlet
Pigtail with
Cylinder Connection
Inlet Gauge,
Right Bank
Inlet
Auxiliary
Inlet
3