ERROR CODES
The radio is equipped with multiple protection functions. If an error occurs, the RX/
TX indicator light will illuminate yellow, and the LED display will show the
applicable error code:
E1: Voltage too low
E2: Voltage too high
E3: WX function invalid
E4: Current BAND invalid
E5: TX SWR too high
SPECIFICATIONS
Frequency Range
Frequency Band
Channels
Frequency Control
Frequency Tolerance
Temperature Range
Microphone
Input Voltage
Dimensions (in mm)
Weight
Antenna Connector
GENERAL
28.000-29.695MHz (PC Programmable)
L / H band: A/B/C/D/E/F. WX/VHF RX: 140-170MHz
480 channels (40 programmable per band)
Phase-Locked-Loop Synthesizer
± 5.0 ppm
-20℃ to +50℃
With push-to-talk [UP]/[DN] bottons and coiled cord
13.8V
287(L)x200(W)x61(H)
1.5kg
UHF, SO239