DUCTMATE Ultimate Door II Instructions d'installation - Page 2
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} DUCTMATE Ultimate Door II. DUCTMATE Ultimate Door II 2 pages.
P A C K A G I N G I N F O R M A T I O N A N D S I Z I N G G U I D E L I N E S
ULtimate Door II
WELD ON
* Insert S4 for Stainless Steel (provided with Stainless Steel hex bolts).
* Insert BI for Black Iron.
Items in Bold refer to hinged doors.
Custom Sizes Available Upon Request - Additional leadtimes may apply
Part #
DW66UL*
UL Door Only
DWH66UL*
DW66ULWS*
UL Door with Insulation Kit and 12" x 12"
DWH66ULWS*
Outer Plate
DW106UL*
UL Door Only
DWH106UL*
DW106ULWS*
UL Door with Insulation Kit and 16" x 12"
Outer Plate
DWH106ULWS*
DW1010UL*
UL Door Only
DWH1010UL*
DW1010ULWS*
UL Door with Insulation Kit and 16" x 16"
DWH1010ULWS*
Outer Plate
DW128UL*
UL Door Only
DWH128UL*
DW128ULWS*
UL Door with Insulation Kit and 18" x 14"
Outer Plate
DWH128ULWS*
DW1814UL*
UL Door Only
DWH1814UL*
DW1814ULWS*
UL Door with Insulation Kit and 24" x 20"
DWH1814ULWS*
Outer Plate
DW2020UL*
UL Door Only
DWH2020UL*
DW2020ULWS*
UL Door with Insulation Kit and 26" x 26"
DWH2020ULWS*
Outer Plate
DW2418UL*
UL Door Only
DWH2418UL*
DW2418ULWS*
UL Door with Insulation Kit and 30" x 24"
DWH2418ULWS*
Outer Plate
Kit 1: Four 8" extension studs, washers,
ULINSULKIT
fasteners, "Do Not Obstruct" stickers, and
installation instructions
OP_UL*
Kit 2: UL Door Outer Plate
INSERT SIZE
Description
Fittings for Hood and Duct Penetration Grease
Opening
Minimum Duct
Door Size
Size
6" x 6"
8" x 8"
6" x 6"
8" x 8"
10" x 6"
12" x 8"
10" x 6"
12" x 8"
10" x 10"
12" x 12"
10" x 10"
12" x 12"
12" x 8"
14" x 10"
12" x 8"
14" x 10"
18" x 14"
20" x 16"
18" x 14"
20" x 16"
20" x 20"
22" x 22"
20" x 20"
22" x 22"
24" x 18"
26" x 20"
24" x 18"
26" x 20"
Unlike the ULtimate Sandwich® style door, the ULtimate II weld on
door requires minimal additional clearance. The duct only needs to be
large enough to accommodate the frame and satisfy the NFPA 96
Standard. Although the frame only extends 1" past each side of the
opening, the NFPA 96 standard requires a minimum of 1.5"
clearance between the opening and all seams or edges. Therefore, a
minimum of 1.5" clearance is recommended on each side of the
opening. In order to use the minimum duct height, the door must be
installed with its longest dimension running horizontally along the
length of the duct.
Duct Access Door
Height
9"
9"
9"
9"
13"
13"
11"
11"
17"
17"
23"
23"
21"
21"
Listed
88VF
Weight
20.0 lbs.
23.0 lbs.
26.7 lbs.
42.5 lbs.
38.1 lbs.
32.5 lbs.
34.95 lbs.
56.5 lbs.
40.0 lbs.
40.9 lbs.
53.0 lbs.
55.0 lbs.
46.22 lbs.
41.3 lbs.
53.0 lbs.
53.7 lbs.
32.6 lbs.
34.0 lbs.
53.0 lbs.
52.0 lbs.
34.95 lbs.
36.9 lbs.
34.95 lbs.
37.0 lbs.
23.5 lbs.
24.3 lbs.
36.0 lbs.
36.8 lbs.
1.12 lbs.
Consult
Factory