Anywave TRN-U1D Manuel de démarrage rapide - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Anywave TRN-U1D. Anywave TRN-U1D 16 pages.
7. Continue to slowly raise the FWD power until you reach the rated power (200W
before BPF in ATSC), or your desired TPO. Be careful to make small increases
in the value of POWER as you approach the desired output level.
8. Check the SNR and Shoulder (LIMD and UIMD) RF performance of your
system on the Exciter hi-level status screen, as well as the exciter's pages on the
PA's touchscreen as shown below. Linear and Non-Linear corrections were
already performed and optimized at a TPO of 200W (before BPF, in ATSC) in
the factory and so the stored correction coefficients should produce good results.
ACT-PA-U1D-QSG-DOC-V2.2, 09/25/2019
TRN-U1D-C-FA Quick Start Guide
Page 11 of 16
Monitor FWD
SYS POWER