1.3 Technical Specification
Needle system:
Maximum number of stitches:
Maximum stitch length:
Maximaler pressure foot stroke:
Clearance under the pressure feet:
when sewing:
when raised:
Maximum thread thickness:
Operating pressure:
Line pressure:
Air consumption per work cycle:
-171110
-171521
Through-feed area:
1.4 Optional Equipment
195 5002
Z 133 601
Z 132 1501
6
933
4000 rpm
dependent on pressure foot stroke
and stitch length
Upper transport 10 mm
Lower transport 8 mm
2-7 mm
10 mm
17 mm
20/3 Nm
6 +/- 0,5 bar
7-10 bar
0,05 Nl
0,1 Nl
280 x 132 mm
Parts set for converting a single-needle
to a two-needle machine. Max. needle
pitch 14 mm dependent on the E-Nr.
Not for 195-171521.
Reflecting light barrier for recognizing
the seam end.
Needle cooling from above.