STEP 12 CONNECT DRAIN LINE
FOLLOW ALL LOCALCODES
AND ORDINANCES
The drain hose molded end will fit 5/8", 3/4" or 1"
diameter connections on the air gap, waste tee or
disposer.
Cut the marked line as required for your
installation.
Cutting
Lines
IMPORTANT: Do not cut corrugated
portion
of hose
Figure20
DRAIN LINE INSTALLATION
Connect drain line to air gap, waste tee or disposer
using either of the previously determined method.
Method 1 - Air gap with waste tee or disposer
E
Waste Tee Installation
Disposer Installation
Figure22
• If a longer drain hose is required, add up to 42"
length for a total of loft. to the factory installed
hose. Use 5/8" or 7/8" inside diameter hose and
a coupler to connect two hose ends. Secure the
connection with hose clamps.
Coupler
_p
Hose Clamp
Figure 21
• Secure the drain hose to the air gap, waste
tee or disposer with clamps.
NOTE: TOTAL DRAINHOSELENGTHMUSTNOT EXCEED
10 FEETFOR PROPERDRAINOPERATION.
Method 2 - High drain loop with waste tee or disposer
Fasten to underside
_
of countertop
3
Waste Tee Installation
m
m
Figure 23
Fasten to underside
_
of countertop
Disposer Installation
IMPORTANT-
When connecting the drain line to
__
Remove
the disposer, check to be sure that
[_
hopper
the drain plug has been removed,
plug
DISHWASHER WILL NOT DRAIN IF
PLUG IS LEFT IN PLACE.
TIP: Avoid unnecessary service call charges. Always
be sure disposer drain plug has been removed before
attaching dishwasher drain hose to dispenser.