TRUCK REQUIREMENTS

Truck Relief Setting
160 bar Recommended
210 bar Maximum
Truck Flow Volume
55G
100G
➀ Cascade K-Series Fork Positioner/Sideshifters are compatible
with SAE 10W petroleum base hydraulic fluid meeting Mil. Spec.
MIL-0-5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact Cascade.
➁ Flow less than recommended will result in slow fork positioning
speed.
➂ Flow greater than maximum can result in excessive heating,
reduced system performance and reduced hydraulic system life.
Carriage Mount Dimension A-
A
Class II
Class III
GA0028.eps
Auxiliary Valve Functions
Check for compliance with ISO standards:
GA0082.eps
WARNING: Truck control handle and
attachment function activation shown
here conforms to ISO 3691 recommended
practices. Failure to follow these practices
may lead to serious bodily injury or property
damage. End user, dealer and OEMs should
review any deviation from the practices for
safe operation.
6047782-R2 EN
Min.
Recommended
15 L/min.
20 L/min.
20 L/min.
30 L/min.
Minimum
Maximum
380.0 mm
381.0 mm
474.5 mm
476.0 mm
Tilt Forward
Hoist Down
Hoist Up
Tilt Back
Max.
35 L/min.
40 L/min.
ISO
Sideshift Left
Spread Forks
Close Forks
Sideshift
Right
Carriage – Clean and inspect carriage
bars. Bars must be parallel and ends
flush. Grind smooth any protruding welds
that may affect Sideshifter lower bearings.
Repair any damaged notches.
GA0131.eps