Dukane iQ Series Mode d'emploi - Page 2
Parcourez en ligne ou téléchargez le pdf Mode d'emploi pour {nom_de_la_catégorie} Dukane iQ Series. Dukane iQ Series 4 pages. Thruster from a plc ultrasonic welders
Également pour Dukane iQ Series : Note d'application (16 pages)
DUKANE
CONNECTING A 43Q220-P-301 THRUSTER TO A PLC
The cable is provided with a connector on both ends. If desired cut the connector from one end to expose the individual
wires. Below are the pins used for thruster control. At minimum only 4 connections are needed. The Top of Stroke,
Trigger and Dual Pressure Valve connections are optional if additional functionality is desired.
It is recommended that an E-stop be inserted between the 24 volt power supply and the cable connection. This will turn
both valves off, allowing the thruster to go to a neutral state. The 24 volt power supply should be capable of supplying
0.5 amps or more.
AN532 (Rev. 00)
Page 2 of 5
Thruster Cable part number: 200-1413
Wire Color
BLK/RED
BLK/GRN
BLK/BLU
BRN/BLK
ORN/BLK
BLU/RED
YEL/RED
GRN/RED
APPLICATION NOTE AN532
Pin no#
1
3
5
9
Top of Stroke (relative to GND)
15
23
20
Dual Pressure Valve
24
Function
22 Volts
Up Valve
Down Valve
Trigger
Trigger return
GND
© Dukane 2021. All Rights Reserved.