Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Abundant Flow Water Zoi DFK-Zeta. Abundant Flow Water Zoi DFK-Zeta 16 pages. Reverse osmosis water filtration system zoi series; mb-1812-50f
2. Locate cold-water angle shut off valve underneath the sink,
usually on the right side, and turn it off. Open cold water faucet
to release the pressure. On single handle faucets, turn the hot
water off to prevent cross over. If water is not stopped
completely, turn off main water supply
3. The angle shut of adaptor is installed directly on the on the cold
water angle shut off valve.
Flex line Instructions
Loosen nut and separate cold water line
from angle shut off valve. Ensure the O-
ring is in place on the angle valve
adapter and screw in place on the angle
shut off valve. If washer in flex line is
worn
or
damaged,
continuing to prevent any leaks. Gently
bend flex line so that it will fit over the
angle valve adapter and tighten flex line
onto angle valve adapter.
Copper Instructions
Loosen nut and separate cold water line
from angle shut off valve. You will need
to cut a piece of the copper tube about
3/4" to 1" (measure to determine the
exact cut needed) so the angle valve
adapter can fit between the angle shut
off valve and the copper line. Ensure the O-ring is in place on
the angle valve adapter and screw in place on the angle shut off
valve. If washer in copper line is worn or damaged, replace
before continuing to prevent any leaks. Push the copper pipe
into the angle valve adapter and tighten down the compression
nut.When connecting the system the feed water line connects
to the angle valve adapter.
Drain Saddle Installation:
The drain saddle consists of two (2) halves, (one half has a fitting
on it), two (2) bolts with nuts, & a rubber seal. It is used to direct
the waste water from your system down the drain. Depending on
where the saddle is located, you may hear water running down
the drain when the system is making water, this is normal. If the
sound is annoying, the drain line may be pushed farther in to help
8
replace
before
Revised 10/2014
NOTE: The system will automatically turn on whenever water is
drawn out of the tank. When the system is on & making water
there will be water going down the drain, this is normal. Once the
tank is full pressure build up in the system will activate the auto
shut off valve, cutting the water supply to the membrane and
stopping the flow of water down the drain. How long it takes for
the wastewater to shut off depends on many variables, including
the amount of water taken out and water pressure.
System Maintenance
Filters:
Filters need changed regularly to ensure protection of the
membrane and high purity water production.
Refer to the chart below for the specific filter set needed for your
system. Filter kits, as well as individual and specialty filters may be
ordered securely online at www.afwfilters.com or by calling 785-
735-9769. With average usage and normal water conditions filters
should be changed every 6 months. The more water you use or
the dirtier your water the more often you will want to change
filters. If the first filter (sediment filter) gets dirty quickly it may
need changed more often than the rest, part number for the
individual sediment filter is RF-SED10-5. All filters (excluding the
membrane) should be changed at least every 12 months.
To change filters:
Note: The tank will need to be emptied when changing filters. If
you would like to save the water in the tank for use, follow the
instructions below, opening the faucet and collecting the water
from the tank after turning the feed water off.
©2014 Abundant Flow Water Systems, Inc.
13