Danfoss 175X0329 Instructions d'installation - Page 3

Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} Danfoss 175X0329. Danfoss 175X0329 4 pages. Installation box

Danfoss 175X0329 Instructions d'installation
Installation Instructions
3.6 X52 Profibus M12 Female
For non-used connectors. Keep blind plugs installed to
connectors at all times to keep the enclosure tight.
General ratings
30 V DC, max. 1 A
Front/screw mounting IP66, UL type 4
Tightening torque: 0.2–0.3 Nm.
Pin
Label
1
Brown
2
White
3
Blue
4
Black
Table 3.6 Wire/Connector Assignment for Plug X52
Mating part: Profibus X52 and X51 (female/male)
Phoenix order No.: SAC-2P-MSB/ XX,XX-910/FSB SCO CT
XX,XX is the cable length in [m, cm]
3.7 LCP Connector
The LCP cable is only used during installation/commissioning.
The plug on the LCP connector must be mounted after use.
The Danfoss part number for the LCP cable is: 175N0162.
4 Installation
CAUTION
HIGH VOLTAGE
Potentially lethal voltage is present on the installation box.
Mount the correct branch circuit protection fuses
and the inverter before connecting the installation
box to the mains.
1.
Mount the installation box on a flat, solid surface.
2.
Connect the PE terminal to ground.
3.
Connect the motor cable to plug X2 on the instal-
lation box.
4.
Connect the mains cable to plug X1 on the instal-
lation box.
VLT® Decentral Drive FCD 300
Installation Box (175X0318/0320/0329)
MI04F102 – Rev 2013-11-25
3