Danfoss CET2000B-RF + RX1-S + CS2 Manuel de l'utilisateur - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Danfoss CET2000B-RF + RX1-S + CS2. Danfoss CET2000B-RF + RX1-S + CS2 12 pages. Wireless electronic hot water cylinder thermostat
size of boiler and the heat exchanger inside the cylinder.
The water heating will not work if a time switch or programmer
has switched it off. And the cylinder thermostat will not always
switch the boiler off, because the boiler sometimes needs to heat
the radiators.
Cylinder thermostats or cylinder sensors are fitted directly to the
surface of the cylinder. The cylinder thermostat (or temperature
controller when used with sensor) will have a temperature scale,
and it should be set at between 60°C and 65°C, then left to do its
job. This temperature is high enough to kill off harmful bacteria
in the water, but raising the temperature of the stored hot water
any higher will result in wasted energy and increase the risk of
scalding.
If you have a boiler control thermostat, it should always be set
to a higher temperature than that of the cylinder thermostat. In
most boilers, a single boiler thermostat controls the temperature
of water sent to both the cylinder and radiators, although in
some there are two separate boiler thermostats.
Danfoss Heating
5