Installation for TWC function (tap water control)
Application
In the TWC mode, the expansion module ensures that outgoing hot tap wa-
and heat water circulation have a sufficiently high temperature, to prevent the pre-
sence of Legionella bacteria .
TWC operation is achieved by setting the switch according to the figure .
Required accessories
2 PT1000 strap-on temperature detectors with 2 m of cable, item
086U3365 (item number corresponds to 1 transmitter)
One of the following modular cables:
Modular cable 0.3 m, item no. 086U4227
Modular cable 1.1 m, item no. 086U4228
Modular cable 10.0 m, item no. 086U4229
Connection block, item no. 086U5121
System image
Expansion module
tWc function
Modular cable
DHP-R Eco
Cooling agent circuit
Sensor, water heater
A strap-on temperature detector is connected on the supply line lead of the end heater, before the mixing valve.
Sensor, hot water return
A strap-on temperature detector is connected on the return lead of the warm water circulation, before the circulation
pump .