6.
Remove the pistons, retaining plate, retaining ball, spring guide
and spring from the cylinder barrel.
7.
Remove the cylinder barrel.
2
8.
Remove the port plate.
9.
Gently lever the valve plate assembly free with the aid of a
screw-driver.
10.
Replace the O-rings and the back-up rings on the valve plate.
Mount the new back-up rings on the new valve plate first and
then mount the new O-rings.
Mount backup ring first
Then mount the O-ring
DKCFN.PI.013.EF4.02
521B0741