Danfoss APP W HC 24 Manuel d'entretien - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Danfoss APP W HC 24. Danfoss APP W HC 24 20 pages. Disassembling and assembling
Service guide | Disassembling and Assembling, APP 21 - 46 and APP W HC 15 -30
4 | 180R9406 | AX274339308034en-000302
8. Using a 13 mm combination wrench,
remove all the bolts on the mounting
flange except the three shown in the next
picture.
WARNING:
Do not loosen the two screws keeping
swash plate in place.
10. Screw the eye bolt in the M8 hole in the
middle of the flange. Pull it straight
upwards.
12. Remove by hand the pistons one by one.
Be careful not to scratch the pistons. Tilt
the retainer plate to horizontal position for
easy removal of pistons, if required.
WARNING:
Do not use any tools.
9. Unscrew the remaining three bolts. Turn
each bolt one round at the time to make
sure that the flange is removed as straight
forward as possible.
11. Swash plate must be placed so that its
surface is not scratched. For further
disassembling of swash plate, see page 10.
13. Remove the retainer plate and the retainer
ball.
Warning: So not loosen the three screws
in the retainer plate.
© Danfoss | 2023.03