Service guide
6
Disassembling and assembling iSave 21
13.
Unscrew high-pressure bearing using a
special socket.
15.
Gently lift the valve plate assembly free
with the aid of the screwdrivers.
17.
Replace the O-rings and the back-up rings
on the valve plate.
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
14.
Remove the high-pressure bearing.
16.
Gently remove both valve plates.