Danfoss PAH 10 Démontage et assemblage - Page 5
Parcourez en ligne ou téléchargez le pdf Démontage et assemblage pour {nom_de_la_catégorie} Danfoss PAH 10. Danfoss PAH 10 20 pages.
Également pour Danfoss PAH 10 : Manuel d'instructions (12 pages)
Instruction
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
13.
Loosen the valve plate using two screw-
drivers. Place one of the screwdrivers in the
slot of the valve plate.
15.
Remove the five O-rings and the five
back-up O-rings.
17.
Wash all parts and replace all seals
(inclusive shaft seal).
19.
If the pump has failed, the reason for the
failure must be found and fixed before the
repaired pump is re-installed.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
14.
Remove the valve plate.
16.
Remove the port plate from the flange.
18.
Inspect all parts carefully (see "Inspection")
and replace any worn parts.
5