3. Mount the O-ring on the flange.
5. Mount the valve plate with seals on the
cylinder barrel.
7. Check that the gap between the cylinder
barrel and the valve plate is 1.5-2.5 mm.
180R9095 | 521B0986 0 | DKCFN.PI.010.NA4.02| 06.2017
Guide pin
4. Mount the port plate in its right position
using the pin as guide.
6. Press the valve plate into the cylinder
barrel using a piece of plastic.
8. Mount the cylinder barrel in the flange.