Danfoss 176F4045 Manuel d'installation - Page 13
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Danfoss 176F4045. Danfoss 176F4045 16 pages. In-back/out-back cooling kit for fa09-fa10, frequency converters
In-back/Out-back Cooling Kit for FA09-FA10
Installation Guide
1
2
3
Illustration 10: Installation of Lower Duct
1
Frequency converter
2
Holes for attaching duct
3
Lower duct
2.9 Installing the Back Vents
To install the upper and lower back vents, use the following steps. Refer to
Procedure
1.
To install the upper back vent, use the following steps:
a.
Slide 6 clip-on nuts over the edge of the upper vent opening in the back plate of the cabinet.
b.
Seat the clip-on nuts into the 6 holes around the opening.
c.
Affix 2 upper vent gaskets to the flange of the upper back vent, placing 1 gasket on the inner side and 1 gasket on
the outer side of the flange.
d.
Slide the upper back vent into the opening in the back plate.
e.
Fasten 6 M6x12 screws around the inner edge of the upper back vent.
Danfoss A/S © 2022.03
4
Screw
5
Top flange of duct
6
Front of duct
Illustration
11.
AN371942471353en-000101 / 136R0248 | 13
Installation
4
5
6