3) PRODUCT INFORMATION
a)
DEFINITIONS/GLOSSARY
Ullage
Outlet
Vent
Brimful Tank Capacity
Nominal Tank Capacity
Usable Capacity
Matching
Days to Empty (DTE)
RF
KgCO
2
SETUP mode
LEARN mode
NORMAL mode
CURRENT information
screens
HISTORICAL information
screens
b)
TECHNICAL SPECIFICATIONS
Tank Size
Minimum Depth :
0.5m
Maximum Depth:
3m
Display
Multi-function LCD display including:
10 bar-graph level indication on both Apollo Smart
Monitor and Transmitter*
Display of various current and historical values (Apollo
Smart Monitor only)
Display control with five control buttons.
Red LED for low level indication at 5% or less of usable fuel
remaining.
Audible alarm sounds every hour on the hour when the tank
level is low.
Max communication distance
Typically 150m in normal 'line of sight' conditions
Power Supply
Apollo Smart Transmitter - Transmitter: 3V LiMn cell, CR2450
Apollo Smart Monitor - Receiver: 5V DC (40mA)
Apollo Smart Monitor – Back up battery: 3V LiMn cell, CR2450
c)
Notes:
Please retain this product manual and the installation guide. It
contains practical instructions, technical specifications and safety
precaution warnings you should know about.
The technical specifications for the Apollo Smart, the contents of
this manual and the images herein are subject to change without
notice.
The contents and images in this manual are subject to copyright
and may not be reproduced without the permission of Dunraven
Systems Limited.
The distance from the Apollo Smart Transmitter to the surface of the liquid in the tank.
The connection point from which oil is drawn from your tank to feed to your boiler. It is typically located 8 cm
above the bottom of your tank in one of the sidewalls. Oil below the outlet level is not usable. For Top
Discharge tanks, the feed point is typically located at 8cm above the bottom of the tank.
A small chimney like feature on the top of your tank. It allows the air within the tank to be released when the
tank is being filled.
The maximum amount of liquid that can fit in the tank.
Normally 95% of the brimful capacity. This is the maximum amount to which your tank should be filled
according to OFTEC and EN standards.
The nominal capacity of the tank minus the amount of oil that is below the outlet or discharge point. If the oil
level falls to the level of the outlet, your tank is effectively empty.
The process of uniquely matching the Apollo Smart Transmitter with the Apollo Smart Monitor.
A prediction of the number of days in which the oil level will reach the outlet or the discharge point. The DTE
is calculated based on the your recent usage patterns.
Radio Frequency - the tank level measurements are conveyed wirelessly to the Apollo Smart Monitor from the
Apollo Smart Transmitter using RF transmissions
Kilogrammes of Carbon dioxide.
SETUP mode is used to configure the Apollo Smart Monitor for your oil tank.
LEARN mode is used to match the Apollo Smart Transmitter with the Apollo Smart Monitor
NORMAL mode is for day to day use of your APOLLO SMART. In this mode it displays current and historical
information.
Screens in NORMAL mode that display information about the current status of the amount of oil remaining in
your tank in Litres, as a %, and the DTE.
Screens in NORMAL mode that display information about your historical usage of oil in terms of litres, cost,
and environmental impact.
Mains Power Supply (included) for Apollo Smart Monitor
150V-240V, 50-60 Hz, meets EN60335
Battery Life
Apollo Smart Transmitter: 5 years (estimated life)
Apollo Smart Monitor – Receiver memory back-up battery: 3yr
if device is not plugged in**
Wireless com:
433MHz FM transmission (EN300-220)
Dimensions
Apollo Smart Transmitter: 140m x 70mm x 40mm
Apollo Smart Monitor: 120mm x 90mm x 50mm
Max and Min Operation (Transmitter)
Operating temperature range: -10°C to +60°C
Operating Humidity : 0 -95% non-condensing
Hole size for fitting transmitter:
32mm diameter
* The Apollo Smart Transmitter and Apollo Smart Monitor bar-graph displays may
differ (see Display symbol reference table).
** This device contains a small battery to keep time during power cuts. If the device
is left unpowered for an extended period then the battery will deplete.
When used according to recommendations, the Apollo Smart
monitors the oil level in your tank and calculates
and presents figures relating to the remaining oil, the historical
usage, and the related monetary and environmental costs. The
Apollo Smart must not be used as verification of a 'Weights and
Measures' certified dispensing meter.
Patents pending or covered by one of the following patents:
S2003/0882, EP2131164 (A1), US2006261966 (A1),
US7277020 (B2), IE20030882 (A2) , S2008/0466,
US2009/0303059 A1