This manual is designed to be a quick start guide for the most common type of installation, for the Airwell Monobloc
range.
This shows heating via Buffer Tank and domestic hot water via a cylinder, with a sensor pocket and immersion
heater installed, using 1x 3 port drive open valve to control space heating and Hot water heating demand using
the Airwell controller and third-party control for the end user control.
In the above system the monobloc unit functions are controlled by the unit's own controller and this is for use
by the technician. End user control is via Third Party controls.
The end user controls the heating demand via the third-party controller.
The heat pump controls the domestic hot water temperature itself (including an optional sterilization cycle
assisted by the immersion heater) using a drive open 3 port valve in a W plan heating configuration.
The hot water temperature is managed through the Airwell Controller. Hot water takes priority over heating.
There is no electric heater installed inside the monobloc unit.
There is a Flow sensor, Pump, Auto Air Vent, Safe Relief valve and 8lt Expansion vessel located within the monobloc
unit.
There is a pump installed within the monobloc, however a second pump will be required on downstream of the buffer
to feed the heating circuits.
A strainer must be installed in the return pipework to the mono block this is included with the unit. It is strongly
recommended by Airwell in addition to this, a Magnetic filter and Flow setter should also be installed to the unit.