Duo-Therm 3109228.001 Manuel d'utilisation - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Duo-Therm 3109228.001. Duo-Therm 3109228.001 9 pages. Duo-therm comfort control center

Duo-Therm 3109228.001 Manuel d'utilisation
(
)
D. Zone Control continued
4 illuminated in the LCD readout. In the event your vehicle
has multiple zones designed, you have the freedom of
selecting the MODE of operation for each zone indepen-
dently. To change from one zone to another, depress the
ZONE push-button. Each time you depress and release
this push-button, the indicator will change the zone data
displayed. The zone number flashing indicates zone
being programmed. The zone number will flash for
approximately 30 seconds unless another zone is se-
lected or programming has been completed. At this time
the number will stop flashing and the desplay light will go
out.When all zones have been programmed, the zones
in operation will be underlined. To program each zone,
simply repeat the programming steps shown in the
operation section of this manual. Please note: The
Comfort Control Center will prevent operating FURNACE
and COOL or FURNACE and HEAT PUMP at the same
time.
E. STAGE CONTROL OPERATION
If your vehicle is equipped with a Duo-Therm Dual
Basement Air Conditioner or a Dual Basement Heat
Pump, you have an air conditioning system that is
designed to optimize comfort and running efficiencies.
(Two units within one compartment). This is accom-
plished as long as the required electrical power is
available, by providing an on-demand secondary stage of
operation. (NOTE: The primary stage will continue to
operate even if there isn't enough electrical power avail-
able to run the second stage.) The Comfort Control
Center simplifies this operation and allows you to set the
primary temperature set-point while the differential tem-
perature set-point which activates the secondary stage
is preset. After turning on your Comfort Control Center,
perform the following steps to set and activate the stage
control operation.
1) Momentarily depress the ZONE push-button to select
stage in the zone desired
2) Momentarily depress the MODE push-button to select
"ON".
3) Momentarily depress the ZONE push-button to select
the zone where stage was selected in Step 1.
4) Momentarily depress the MODE push-button until the
desired mode of operation is selected (FAN ONLY,
COOL or HEAT PUMP).
5) Momentarily depress the FAN push-button until the
desired fan speed is displayed (LOW, HIGH or AUTO).
6) Momentarily depress the UP and DOWN push-button
until the desired room temperature set-point is dis-
played.
72
6
MODE
LOW HIGH
LOW HIGH
MED
MED
AUTO
AUTO
°F
SET POINT
MODE
FAN
UP
FURNACE
TEMP
DOWN
ZONE 1 2 3 4
ZONE 1 2 3 4
ZONE
PUSH
OFF
OFF
ON
ON
2
4
MODE
LOW HIGH
LOW HIGH
MED
MED AUTO
AUTO
MODE
FAN
5
FAN ONLY
FAN ONLY
UP
6
TEMP
DOWN
ZONE 1 2 3 4
ZONE 1
2 3 4
STAGE
ZONE
1 3
OFF
OFF
ON
ON