Operation
The DAN WR3-2 is switched on automatically when the sensor is immersed in
water and can be switched off by pressing the on/off button.
The light can also be activated and deactivated manually by pressing the on/off
button.
Sensor
Switch
Figure depicts the Sensor Switch and the Manual ON/OFF Button
Maintenance
Routine service
Dan WR3-2 is maintenance free, but the following checks must be made
annually:
1. Inspect the light for signs of damage or corrosion.
2. Press the on/off button and the light will commence flashing then press
the button once more and the light should deactivate.
3. To test the Cable and the Sensor Switch – a Metal paper clip may be
applied to the 2 water contacts. It is recommended that the light is
activated for 1 minute.
Replacement
The Dan WR3-2 lifejacket lights have a storage life of 5 years and must be
replaced by the date shown on the label.
Health and safety information
Dan WR3-2 lights contain Lithium cells. These must be handled correctly:
Do not dismantle the light assembly
Do not make any external electrical connection
Do not recharge
Do not incinerate
Store between -30°C and +65°C
3
ON/OFF
Button