TROUBLESHOOTING:

PROBLEM
1. Control   d ial   i s   o ff   a nd   u nit   i s
clicking/4cking
2. The   u nit   i s   4 cking/clicking  
while   t he   h eater   i s   l it.
3. Fan   d oes   n ot   t urn   w hen
electrical   c onnec4on   i s   m ade.
4. Heater   w ill   n ot   fi re.
5. Heater   q uits   w hile
running.
Always be sure to follow proper maintenance procedures, by cleaning the heater once per
month during regular usage, and check spark gap at least once per season.
10
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING
POSSIBLE   C AUSE
1. This   h eater   u ses   a   c on4nuous   s park
igni4on   s ystem.   T his   u nit   w ill   c on4nue
to   m ake   a   c licking/4cking   s ound   a t   a ll
4mes   b efore   i gni4on,   a Aer   i gni4on
and   d uring   o pera4on,   r egardless   o f
valve   k nob   p osi4oning.
1. This   h eater   u ses   a   c on4nuous   s park
igni4on   s ystem.   T his   u nit   w ill   c on4nue
to   m ake   a   c licking/4cking   s ound   a t   a ll
4mes   b efore   i gni4on,   a Aer   i gni4on
and   d uring   o pera4on,   r egardless   o f
valve   k nob   p osi4oning.
1. No   e lectric   p ower   t o   h eater.
2. Fan   b lade   c ontacts   i nside   o f   h eater   h ousing.
3. Fan   b lade(s)   b ent
4. Fan   m otor   d efec4ve.
1. No   s park   a t   i gnitor.
2. Improper   s park   g ap.
3. Bad   e lectrode.
1. Internal   t emperature   t oo   h igh   c ausing   l imit  
switch   t o   s hut   d own   o pera4on.
2. Damaged   C ontrol   V alve.
3. Dust   o r   d ebris   b uild-­‐up   i nside   o f   h eater.
CORRECTIVE   A CTION
1. No   c orrec4ve   a c4on   i s   n eeded.
1. No   c orrec4ve   a c4on   i s   n eeded.
1. Check   c urrent   t o   e lectric   o utlet.   I f   v oltage   i s   c orrect,
check   p ower   c ord   a nd   e xtension   c ord   f or
2. Be   s ure   t hat   h ousing   i s   n ot   d amaged.   M ake   s ure
there   a re   n o   o bstruc4ons   t o   t he   f an.
3. Straighten   b lade(s)   t o   m atch   o thers.
4. Replace   m otor.
1. Check   i gnitor   w ire.   R e-­‐aQach   o r   4 ghten   i f   l oose.
Check   S park   m odule.   R eplace   i f   n ecessary.
2. Set   g ap   ( See   s pecifica4ons   f or   g ap).  
3. Replace   S park   P lug.
1. If   t he   h eaters   o utput   i s   r estricted,   i nternal   t emperature
becomes   t oo   h igh.   M ove   h eater   a way   f rom
any   o bstruc4ons.
2. Replace   C ontrol   V alve.
3. Clean   i nside   o f   h eater.