IMPORTANT SAFETY INSTRUCTIONS
WARNING: Electrical Precaution; To reduce the risk of electrical shock, connect only to a properly grounded, grounding type
receptacle. The National Electric Code (NEC), Article 680-41(A) requires ground fault circuit interrupter (GFCI) be installed in the
branch circuit supplying fountain equipment. Only a 3-wire grounding extension cord and grounded outlets should be used. If
the extension cord plug can reach the water and be accidentally submerged it should be secured to prevent submersion.
WARNING: Read All Instructions
1. Ground Fault Circuit Interrupter (GFCI) protection is to be provided on the circuit(s) or outlet(s) to be used for the wet location
portable luminaire. Receptacles are available having built-in GFCI protection and are able to be used for this measure of safety.
2. Use only with an extension cord for outdoor use, such as an extension cord of cord type SEW, SEOW, SEOOW, SOW, SOOW,
STW, STOW, STOOW, SJEW, SJEOW, SJEOOW, SJW, SJOW, SJOOW, SJTW, SJTOW, or SJTOOW.
3.
This portable luminaire / ballast assembly has an IP65 rating making it suitable for damp and wet locations when assembled in accordance
with these instructions. Do not submerge ballast.
CONSIGNES DE SÉCURITÉ IMPORTANTES
Utilisez uniquement des rallonges extérieures à trois ls munies de ches à trois broches et d'une prise de terre acceptant la che de
l'appareil. Si le problème persiste, contactez un électricien quali é. Ne jamais utiliser avec une rallonge à moins que la che puisse être
complètement insérée. Ne modi ez pas la che.
AVERTISSEMENT: lisez toutes les instructions
1. Une protection par disjoncteur de fuite à la terre (GFCI) doit être fournie sur le (s) circuit (s) ou la (s) prise (s) à utiliser pour
luminaire portable pour site humide. Les prises sont disponibles avec une protection GFCI intégrée et peuvent être utilisées pour
cette mesure de sécurité.
2. Utilisez uniquement avec une rallonge pour utilisation à l'extérieur, telle qu'une rallonge de type SEW, SEOW, SEOOW, SOW, SOW,
STOW, STOW, STOW, STOOW, SJEW, SJEOOW, SJW, SJOW, SJOOW, SJTOW, SJTOW, ou SJTOOW.
3. Cet ensemble portable de luminaire / ballast a un indice de protection IP65 le rendant approprié pour les endroits humides et
mouillés une fois assemblé conformément aux instructions jointes. Ne pas submerger le ballast.
UV CLARIFIER OPERATING INSTRUCTIONS:
replace an existing UV Clari er or add a second unit to Clearguard Pressure lters.
It can only be used in conjunction with the Clearguard lters indicated above.
INSTALLATION INSTRUCTIONS:
ALWAYS DISCONNECT PUMP BEFORE INSTALLATION.
1) Before installing the UV Clari er assembly into the lter cover, the lamp must
be installed. Carefully unpack the ballast / quartz sleeve assembly and remove the
quartz sleeve by rmly holding the black collar section and turning it count-
er-clockwise until it disengages from the lamp socket assembly.
2) Unpack the lamp and insert the contact pins on the lamp base completely into
the lamp socket.
For the 9 Watt unit: Continue to step 3.
For the 18 Watt unit: Find the lamp retainer in the lamp box and slide it onto
the lamp until it is snug in the socket. Next insert the alignment disk onto the
end of the lamp to keep it centered inside the quartz sleeve.
3) Make certain that the at gasket and O-rings are properly installed. See FIGURE 1.
Flat gasket sits on top of the of the quartz sleeve and O-ring ts outside the tube,
under the top ange. See FIGURE 1
4) Lubricate the Gasket and O-rings with Silicone grease for easier assembly.
Never use petroleum based lubricants.
5) Insert the UV lamp assembly into the Quartz sleeve and hand tighten - turning
clockwise until secure.
6) Insert the lamp / quartz sleeve assembly into either of the UV port openings in
the pressure lter cover.
7) Secure it by rotating the threaded ring of the UV xture clockwise onto the
lter cover's threads until tight.
8) After COMPLETE installation, UV Clari er can be brie y tested; plug the power cord into a grounded GFCI protected outlet to check.
The UV light can be safely viewed through the clear plastic cap on the xture. After testing, disconnect power until the lter is running.
The UV unit should only be powered on when the pressure lter is fully assembled with water circulating.
UV CLARIFIER KIT
MODEL ITEM # Fits Clearguard lter
9 Watt 15810
18 Watt 15820
This UV kit can be used to
Model 2700
Models 5500, 8000 & 16000
UV FIXTURE
WITH BALLAST
THREADED
RING
LAMP SOCKET
WITH SAFETY
SWITCH
UV LAMP
LAMP
RETAINER
ALIGNMENT
DISK
FLAT GASKET
O-RING
UNDER TOP
FLANGE
QUARTZ
SLEEVE
t
NOTE: YOUR FILTER AND
UV ACCESSORIES
MAY VARY FROM
REFERENCE ILLUSTRATION.
DO NOT OPERATE UV
CLARIFIER UNTIL READING
ALL OPERATING
INSTRUCTIONS, NOTES AND
PRECAUTIONS.
le
FIGURE 1
NOTE POSITION OF FLAT
GASKET AND O-RING.
FLAT GASKET
SEATS ON TOP
OF QUARTZ
SLEEVE
POSITION
O-RING
OUTSIDE THE
TUBE, BELOW
THE FLANGE
EXTRA UV
PORT CAP
(removed)
OPEN UV PORT