4. Technical specification.
•
S-IP and S-MP pumps are assembled with a 3-phased motor. Version 2-pol or 4-pol.
50 or 60 Hz after choice. See motor label for accurate motor information on your pump.
•
230/400 or 400/690 after choice. See motor label for accurate motor information on your pump.
•
•
Motor space heater* 1x230vac. 50watt to 100watt. Have to be protected with an extern fuse.
Svend Höyer electric motors are type approved by BV, GL and ABS (design approval).
•
Svend Höyer electric motors are CE marked according to the Low Voltage Directive 2006/95/EC.
•
•
PTC resistance*: 200-250ohm at 20ºC. (U = 7,5V max).
Thermistor. On/off. 135ºc.
•
Ambient temperature: up to max. 40ºC.
•
•
Media temperature: 5ºC to 100ºC
Flange according EN1092-1
•
Pump is based on design according ISO 2858.
•
•
Pump Standard surface treatment: Blue RAL 5010. C5M.
* Only if it is built-in into the motor.
Motor protection.
Degree of protection is standard IP55, and insulation class is F. Tested to standard IEC 60034-2-1.
The IE2 class motor has standard tropical windings.
The IE3 class motor has tropical windings as an option.
Pump material.
Items
Motor < 4 kw.
Motor > 4 kw.
Motor bracket
Back plate
Mech Seal
Pump shaft
Impeller
O-Ring
Volute
Wear rings
For some pump size can impeller i Stainless steel be an option
Danpumps Pumps can be manufactured with other types of Mech. Seal and O-rings for specific conditions.
Pump materiale as standard.
S-IP
Alu.
Cast Iron
Cast Iron
Cast Iron
SiC/C-NITRIL
AISI 329
Bronze Ni.AL.
Nitrile / NBR.
Cast Iron
Bronze Ni.AL.
S-MP
Alu.
Cast Iron
Cast Iron
Bronze RG10
SiC/C-NITRIL
AISI 329
Bronze Ni.AL.
Nitrile / NBR.
Bronze RG10
Bronze Ni.AL.