DIODE MEASUREMENT

Move the rotary dial to the
Contact the red probe to the anode of the measured diode, and the black probe to
the cathode of the measured diode.
The reading on the screen is the approximate value of the diode forward voltage
drop. If it is connected in reverse, it will display "OL".
Warning
Firstly, disconnect the power supply of the circuit and discharge all high voltage
capacitors.
If the diode to be tested is an open circuit or with reverse polarity, the instrument
will display "OL".
After completing all measurements, always disconnect the probe and the
measured circuit.

CONNECTIVITY TEST

Move the rotary dial to the
connectivity function.
Contact the probe to both ends of the measured circuit. When the resistance of the
measured circuit is below 50Ω, the buzzer will sound.
Warning
Firstly, disconnect the power supply of the circuit to be measured and fully
discharge all high voltage capacitors.
After completing all measurements, always disconnect the probe and the
measured circuit.

NON-CONTACT VOLTAGE DETECTION

Move the rotary knob of the instrument to NCV.
Approach the non-contact voltage induction area of the instrument to the live wire
of the AC voltage (less than 5mm).
The non-contact voltage indicating light of the instrument will light up. At the same
time there is a 'beep', which indicates that there is AC voltage on the fire wire.

GENERAL TECHNICAL SPECIFICATION

Environmental conditions
for use
Working environment
temperature & humidity
Storage environment
temperature & humidity
Temperature coefficient
Max. Voltage allowed
between measuring
terminal and ground
Fuse Protection
Sampling rate
position and switch to the diode function.
position, press "FUNC." and switch to the
IEC/EN 61010-1 600V CAT III, pollution level 2, altitude
<2000m
0~40°C
-10~60°C (remove the battery when it is below 70%RH)
0.1 x accuracy/°C
DC or AC 600V RMS
Fuse FF 250mA/600V
About 3 times/second
6