4-noks IntellyGreenPV ZR-TIDCI.D-PV-EM Instructions d'assemblage - Page 2
Parcourez en ligne ou téléchargez le pdf Instructions d'assemblage pour {nom_de_la_catégorie} 4-noks IntellyGreenPV ZR-TIDCI.D-PV-EM. 4-noks IntellyGreenPV ZR-TIDCI.D-PV-EM 2 pages.
WIRING THE DEVICE
Connecting counting input to a clean contact output (S0 output)
Connect S0 output to
terminal (5) and (6)
Connecting alarm input to a clean contact output (S0 output)
Connect S0 output to
terminal (8) and (9)
Waring:
If an optical interface is not used, make sure the counting
input (and alarm input) is connected to outputs with voltage
free contact.
Do not apply differences of potential to these terminals
contacts.
Otherwise, the device may be damaged beyond repair.
OPERATING CONTROLS
Button
If pressed for longer than 10 seconds the device is reset to its original
state (disconnected device).
This action causes the loss of data relating to the radio communication
and the loss of connection with the In-house Display and all devices
connected to it.
LIGHT SIGNALS
Led State
Description
Continuous light orange.
Indicates that the device is not
Short flash every 20
connected to any radio network.
seconds.
Flashing indicates that the
Flashing Green
device is operating normally.
4-noks s.r.l. - Francenigo di Gaiarine (TV) Italy
ASSOCIATION TO THE IN-HOUSE DISPLAY
Normally the device is supplied in the kit along with the In-house Display and
normally the two objects are already connected and therefore able to work
immediately after their powering, without additional configuration.
If for some reason there's no association between the two devices (because
of the disconnection of the In-house Display or Radio Transmitter) you can
connect them again.
Association of the device:
1)
Turn on In-house Display and Radio Transmitter
2)
Verify that the Radio Transmitter is not connected to any radio
network (the LEDs are all switched on and perform a quick flash
for two seconds every 20 seconds), otherwise disassociate the
device by pressing the button for more than 10 seconds.
3)
Acting on the In-house Display, open the radio network
(Menu/Radio Management/ Open Radio Network) following the
steps:
Press the button under "Menu"
Select "Open Radio Network"
A few seconds after opening the network, the device should connect to the
radio network of the remote display. The operation's success is highlighted
by the flashing of led LD1 of the device.
If after 30 seconds from the opening of the network the device is still not
connected, maybe the chosen location is not suitable; in this case place the
device closer to the In-house Display or install another Repeater (ZR-
REPE230M).
When finished, close the radio network via In-house Display.
STANDARDS
Regulations: 2006/95/CE, 89/336/CE, 99/5/CE
Standards:
EN 300 328, EN 301 489, EN 61000-6-2, EN 6100-6-3,
EN 60950-1
Disposal
In case of disposal, the products must be disposed of separately in
accordance with applicable local laws.
Warranty Conditions
The warranty period is 2 years from the date of installation or 30 months
from the date of manufacture.
The warranty applies only in UK.
The manufacturer agrees to replace or repair the components that are
found defective.
Damage caused by improper installation, by a power supply not
compliant with the CEI EN 50160 standard, by the incorrect use or
failure to comply with the instructions contained in the Assembling
Installation is not covered by the warranty.
NOTES:
Select "Open Radio Network"
Confirm this request to open
the In-house Display radio
network
At the end of the association
process, confirm this request to
close the In-House Display
Radio Network
INSTRUCTIONS
INPV
SERIES
001
VERSION
1.4
DATE
06 / 2011