4B HTAS1V34 Manuel d'utilisation - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} 4B HTAS1V34. 4B HTAS1V34 20 pages. Wda sensor belt alignment / motion & broken / slack chain monitor
METAL ELEVATOR BUCKET OPTIONAL FRONT MOUNTING DIAGRAMS -
PULSE
Metal Elevator Bucket
NORMAL RUNNING
METAL ELEVATOR BUCKETS WITH CLOSE VERTICAL CENTERS -
Figure 5 illustrates the optimal WDA sensor placement for elevator buckets with close vertical spacing.
This placement allows for the maximum differential between the buckets. GB Spidex™ and Starco™
low profile are two examples of these bucket types. For additional information, contact 4B.
PULSE
PAGE 11
NO PULSE
Metal Elevator Bucket
BELT MISALIGNMENT
Figure 4 -
Optional Front Mounting Of WDA
Sensor For Metal Elevator Buckets
Figure 5 -
WDA Sensor Placement
For Metal Buckets With
Close Vertical Centers
PULSE