Aplisens SGE-25.SMART Manuel de l'utilisateur - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Aplisens SGE-25.SMART. Aplisens SGE-25.SMART 20 pages. Smart level probes
Également pour Aplisens SGE-25.SMART : Manuel de l'utilisateur (20 pages)
C
1. INTRODUCTION
1.1. This manual is intended for users of SGE-25.SMART, SGE-25S.SMART, SGE-25, SGE-25S, SGE-25C
and SGE-16 hydrostatic level probes containing the data and guidelines necessary to understand the
functioning of the probes and how to operate them. It includes essential recommendations concerning
installation and use, as well as emergency procedures.
1.2. The SGE-25, SGE-25S and SGE-25SMART, SGE-25S.SMART are also made in Ex version.
Additional data on the probes in Ex version is contained in the appendix designated
„DTR.SG...04
During installation and use of the probes in Ex version, reference should be made to DTR.SG...04 in
conjunction with Appendix Ex.
1.3. The level probes: SGE -25, SGE -25S, SGE -25C, SGE -25SMART, SGE -25S.SMART in
realization for sea uses are complied with Det Norske Veritas (DNV) Rules for Classification of Ships,
i
High Speed & Light Craft and Det Norske Veritas' Offshore Standards. Certificate No. A -11311 for
application in following Location Classes: Temperature C, Humidity: B, Vibrations: B, EMC: B,
Enclosure: D.
2. USER MATERIALS
Probes are delivered in single and/or multiple packs. A probe is delivered together with a "Product Certificate"
which also serves as a guarantee card.
Each batch of probes also carries user's manual in quantities agreed with the customer
3. APPLICATIONS OF PROBES
The SGE-25.SMART, SGE-25S.SMART, SGE-25, SGE-25S, SGE-25C and SGE-16 probes are designed to
measure the depth of liquid in wells, swimming pools, watercourses, boreholes etc.
The SGE-25S.SMART and SGE-25S probes are also designed for the measurement of levels of liquid waste
and of dense or viscous.
The SGE-16 probe, due to its small diameter, is designed fir the measurement of water levels in wells and
boreholes, wherever it is necessary to insert probes into pipes of small diameter for which it is impossible to
use the SGE-25.
The probes convert an input pressure (being a measure of the level of the medium) into a standard 4÷20 mA
signal transmitted in a two-wire system (probes SGE-25, SGE-16, SGE-25C, SGE-25S) and a digital communi-
cation signal in the „HART" system (probes SGE-25.SMART, SGE-25S.SMART),or in special versions into a
0÷10V signal transmitted in a three-wire system (applicable only to the SGE-25, SGE-25S, SGE-25C models).
Probes fitted with cables with an additional Teflon shield may be used with food products and with reactive
substances.
4. IDENTIFYING MARKS. ORDERING PROCEDURE
4.1. Identifying marks on a rating plate
Every probe carries a rating plate containing at least the following information: CE mark, numbers of notified
institutions and designations of certificates obtained, name of manufacturer, type, factory number, basic
range, output signal, power supply voltage.
4.2. Ordering procedure
See the catalogue cards.
5. TECHNICAL DATA
5.1. Technical data. SGE-25.SMART and SGE-25S.SMART probes
5.1.1. SGE-25.SMART, SGE-25S.SMART . Measurement Ranges
Basic range
Type of probe
(FSO)
SGE-25.SMART
SGE-25S.SMART 0÷100 m H
Appendix.Ex.04" or „DTR.SG...04
(ENG).
Maximum range
(measurement limits)
0÷10 m H
0
-1÷11,5 m H
2
0
-5÷115 m H
2
6
. Appendix.Ex.03".
(ENG
Minimum
Ability to shift the
set range
start of the range
0
0,8 m H
0
2
2
0
8 m H
0
2
2
DTR.SG...04
.
Overpressure
limit (without
hysteresis)
0÷10 m H
0
30 m H
2
0÷100 m H
0
300 m H
2
(ENG)
0
2
0
2