Aplisens SP-11 Manuel de l'utilisateur - Page 12
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Aplisens SP-11. Aplisens SP-11 16 pages.
IO.ZSP-41.SP-11.SP-02
9.2.
Electrical parameters of SP-11
Two-wire power supply
Power consumption
Input signal
Input resistance
Output signal
Output resistance
Insulation type
Resistance to electrical breakdown
Conversion errors
- basic error (***)
- temperature change effect
- load resistance change effect
- power voltage change effect
(***) ERROR VALUE REFERS TO RANGE SETTING 4...20mA/4...20mA WITHOUT
POWER SUPPLY TO INPUT CONVERTER. WITH OTHER SETTINGS (WITHOUT
ADDITIONAL CALIBRATION) BASIC ERROR IS 0.25% - not applicable to
9.3.
Electrical parameters of SP-02
Input voltage
Input signal
Output signal
Output resistance
Insulation type
Resistance to electrical breakdown
Conversion errors
- basic error
- temperature change effect
- load resistance change effect
- power voltage change effect
10
9...36 V DC
<1 VA
0...20mA, 4...20mA, 0...5mA, 1...5mA
0...10V, 2...10V
≥ 50kΩ (voltage input)
≤ 50Ω (current input)
4...20mA
0...( Usup[V]-9V)/0,025A [Ω]
Max. 500Ω
optoelectronic
1.5kV AC 50Hz 1min
≤±0.16%
≤±0.1%/10°C
≤±0.1%/100Ω
≤±0.1%
≤ 3.5V + Iout x R
L
4...20mA
4...20mA
0...10V
0...500 Ω (current output)
≥ 2 kΩ (voltage output)
transformer
1.5kV AC 50Hz 1min
≤±0.16%
≤±0.1%/10°C
≤±0.1%/100Ω
≤±0.1%
OWC
version.
03.B.005