Rated voltage
# 612... .. 2 .. ....
# 612... .. 1 .. ....
Max. rated power
Circuit breaker
RCD
Protection degree
Protection class
Pre-installation
> Install electrical connection according to the technical
drawing of the toilet.
DANGER
> Disconnect electrical components from the power supply
before the installation.
> Check that all components are de-energised.
> Prevent the power supply line from being switched on
accidentally by third parties.
> Ensure that there is no damage to the power supply cable.
> Lay a permanent power supply line which must be on a
separate circuit:
> Observe the position of the electrical connection
> Leave at least 800 mm (31½ ") of feed cable exposed
> Install circuit breaker
> If the product itself does not have electrical leakage
protection function, it must be installed in circuit where
there is leakage protection device installed.
> Means for disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules and
having a contact separation in all poles that provide full
disconnection under overvoltage category III conditions.
+
6
23
Connecting the cable
> Remove the insulation from the wires approximately
10 mm (⅜ ").
> Connect the 3 wires to the terminal block. Observe the
L, N and PE conductors.
> Confirm that the grounding wire is 10 mm (⅜ ") longer
than the L and N wire.
6
57361_Mounting_SeWa_Starckf_TW_RE/20.04.2
220 – 240 V 50 – 60 Hz
100 – 120 V 50 – 60 Hz
(Taiwan models)
1080 W
I
= 16 A
N
I
= 30 mA
N
IP X4
1
Risk of fatal electric shock
Cold water
Water pressure
Water hardness
Pre-installation
> Install water connection and water outlet according to the
technical drawring of the toilet.
Health risk and potential product
WARNING
damage!
> Supply the product with tap water from the main water
system only.
> Do not connect any waste water, grey water, industrial water,
sea water or other untreated or semi-treated water.
NOTICE
Product damage due to limescale build-up
In regions with hard water, limescale build-up can impair the
performance of the product.
> Check the water quality in your region. Duravit recommends
the installation of a water softener with water hardness
≥ 14° dH (2.5 mmol/l).
> Make sure to descale the product regularly. The app will
send an automatic reminder. Adjust the descaling settings
according to the water hardness in your region
(→ App: Menu – Care – Descaling).
> Only use descaling agents provided or approved by Duravit.
Water hardness
soft
<8.4° dH (1.5 mmol/l)
moderate 8.4 – 14° dH (1.5 – 2.5 mmol/l)
hard
>14° dH (2.5 mmol/l)
DN15 (½ ")
0.07 – 0.75 MPa
(10 – 109 psi)
max. 2.4 mmol/l (240 ppm)
Descaling cycle
every six months
every six months
quarterly