INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS
1) Place Power Control Unit in a position convenient to work area.
2) Plug Power Cable into any 110-120 Volt, 15 amp service outlet. For uninterrupted operations do not connect
any other equipment that may add a heavy load to the same 15 amp service. If a power extension is needed,
use only a heavy duty 3 conductor cord of suitable quality.
3) Connect the gun control cable plug to the power supply by aligning the pins with those on the receptacle,
rotate connector as required to locate key, push in and rotate lock ring clockwise to lock into place.
4) For standard (straight) weld cable hookup, connect the ground connector to the ground receptacle and the
black gun connector to the gun receptacle. Align the flat on the male end of the connector to the key inside
the female receptacle, push in and rotate connector to the key inside the female receptacle push in and rotate
connector clockwise until it is tight.
Note: If connectors are not locked tightly arcing may occur causing permanent damage to both parts..
5) The ground cable is supplied with a ground or work clamp. Any clamping device suitable for welding can be
used assuming a good electrical connection can be made and produces sufficient clamping pressure.
6) Before any test welding is done, all weld cables should be stretched out in such a manner as to avoid tightly
coiled loops, since this will affect the setup parameters resulting in weld quality variation.
Safety Requirements
1) Comply with all ventilation, fire and other safety requirements for welding as established for construction
and industrial applications.
2) The weld tip and all metal parts in contact with it are all electrified while welding. Always avoid contact of
these components with any metallic item such as jewelry or other metal part or tools.
3) All cables and connections require continual inspection for broken insulation and other electrical hazards.
Repair of these items should be done in compliance with the established safety precautions established for
electrical equipment repair.
Duro Dyne Tech Service Contact Information:
Toll Free: 1-800-899-3876
Mon - Fri: 7:00 am - 7:00 pm EST
TECHNICAL SPECIFICATIONS
CCD110N
ELECTRICAL:
Input voltage: 110-120 V
Dedicated Line 60 HZ
15 amp breaker