Duro Dyne Looped Cable Assembly, Eyelets, and Dyna-Studs are limited to the working load limit of the appropriate
Dyna-Tite Cable Lock used with it. See charts below.
CL6-WC2
IMPORTANT WARNINGS AND RECOMMENDATIONS
When installing Duro Dyne Dyna-Tite cable attachments to buildings or equipment careful consideration must
be made to the attachment method and the material being attached to. It is the responsibility of the installer for
the proper selection, installation and appropriateness of the attachment to the job specifications and any codes.
Duro Dyne can give general guidance, but any questions regarding this should ultimately be directed to the project
engineer of the job.
FOR STATIC LOAD APPLICATIONS ONLY!
ALWAYS CONFIRM ENGAGEMENT OF CABLE LOCK ON WIRE BEFORE APPLYING THE LOAD: By pushing the adjustment pin in the opposite direction of the
arrows on the cable lock and then pulling the cable also in the opposite direction of the arrows on the cable lock.
PULL ADJUSTMENT PIN BACK AND PASS WIRE ROPE THROUGH DYNA-TITE CABLE LOCK: Failure to pull adjustment pin first may cause damage to serrated
teeth and reduce holding capacity.
TO ENSURE HANGING SYSTEM INTEGRITY AND SAFETY: Use only Duro Dyne wire rope.
DO NOT EXCEED THE WORKING LOAD LIMIT (WLL) OF THE CABLE LOCK: Each product is load rated and incorporates a minimum safety factor of 5:1. This WLL
takes into account the specification criteria of the Dyna-Tite Cable Lock and the wire rope.
DO NOT USE ON COATED WIRE ROPE: It is important to maintain the metal to metal contact between the locking pawls in the Dyna-Tite and the wire rope.
DO NOT APPLY PAINT OR OTHER COATING: to any part of the assembly as these may impair the free movement of the locking pawls inside the Dyna-Tite Cable
Lock.
DO NOT APPLY LUBRICANT: to any part of the assembly as this will alter the surface nature of the wire rope and attract dirt and debris.
DO NOT USE FOR LIFTING: (Under Hook slings) This product is designed for static load applications only.
KEEP THE PRODUCT CLEAN AND FREE FROM DIRT: Any dirt should be removed from the product prior to assembly.
INSPECT PERIODICALLY: Upon inspection, discard and replace if worn, distorted, or damaged.
REMOVE DAMAGED WIRE ENDS: Using a designated pair of wire rope cutters prior to inserting into the Dyna-Tite Cable Lock.
FOR DRY LOCATIONS ONLY
DO NOT USE IN CHLORINATED ATMOSPHERES SUCH AS POOLS AND NATATORIUM
GYMNASIUM INSTALLS MUST BE USING LOCKING CABLE LOCKS ONLY
TO ENSURE THE INTEGRITY OF ANY DYNA-TITE CABLE LOCK SYSTEM OR ACCESSORY,
USE ONLY CABLE LOCKS AND WIRE ROPE SUPPLIED BY DURO DYNE.
THE PRODUCTS ARE PROVIDED ON AN "AS IS" BASIS; THERE SHALL BE NO EXPRESS OR IMPLIED
WARRANTY, INCLUDING WITHOUT LIMITATION, WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. SUPPLIER SHALL NOT UNDER ANY CIRCUMSTANCES, BE LIABLE FOR
81 Spence Street • Bay Shore, NY 11706 • Tel: 631-249-9000 • Fax: 631-249-8346
End Fixings Installation Instructions
WORKING LOAD RANGE
Wire Rope
Safe Working Load Range
at 5:1 Safety Factor
10-75 lbs.
WC2-CL6
(5-34 kg)
INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOST PROFITS.
DO NOT EXCEED THE SAFE WORKING LOAD RANGE OF THE PRODUCT
CL18-WC4
Wire Rope
Safe Working Load Range
at 5:1 Safety Factor
25-250 lbs.
WC4-Cl18
(12-114 kg)
®
R
CL12-WC3
Wire Rope
Safe Working Load Range
at 5:1 Safety Factor
25-150 lbs.
WC3-CL12
(12-68 kg)