N.B Make sure that once the extractor is installed there is no accidental access to the moving parts.
Electrical Connections
1. The extractor fan must be connected to a single phase mains network, 220 - 240VAC.
2. The installation must have an omnipolar switch with a contact separation of at least 3mm. The circuit
must be protected by a 3 Amp fuse.
3. Earthing is not required as this extractor is a class II insulated appliance.
4. The extractor must be connected permanently to a fixed installation cable secured in fixed
channelling. (Flex of two conductor wires of minimum section 1mm
To make the Electrical Connections
5. Loosen the 4 screws (A) and take off the connection cover
6. Perforate the flex holder (B) to allow the power supply wires to pass through.
7. Make the connections as indicated on the next page.
A
Mixflo fan
Flexible
screwed to joist
ducting
Internal White
Grille
Body can be rotated to accomodate tight spaces.
B
External
grey grille
and maximum 1.5mm
2
)
2